Vacuum gauge Set DCP 3000 + VSP 3000 Vacuubrand
![Vacuum gauge Set DCP 3000 + VSP 3000 Vacuubrand](/medias/cat-29658-1.jpg?context=bWFzdGVyfHJvb3R8MTIxODh8aW1hZ2UvanBlZ3xoNGUvaDQzLzg4MzMxODk5MzcxODIuanBnfDY4NGE1YzZjYjBiOGNjMTNhYTA5OWEzZmYxNmMwNTQ2YWQ0ZGViNDk1ZTQyNWU1YmE3ZmY5ZmYzZTZmYjg0Mjg)
The DCP 3000 is an outstanding vacuum gauge with large illuminated display. The VSP 3000 vacuum sensor is based on thermal conductivity (Pirani) and offers a wide measurement range from atmospheric pressure down to 10-3 mbar. The wetted parts are made of chemically resistant plastics (PBT, PUR) and alumina ceramics. It features a much better chemical resistance and ruggedness than conventional Pirani sensors with their fragile metallic spiral-wound filament. Simultaneous connection of up to eight vacuum sensors allows flexible measuring on the spot. The DCP 3000 communicates with external components via the VACUU·BUS® digital bus system. It is characterized by fully automatic configuration, unified plug connections and cable lengths of up to 30 m. In addition the DCP 3000 offers relative pressure measurements (VSK 3000 as reference) and a data logger feature for up to 32,000 data values.
Performance features
- up to four gauge heads VSK 3000 (Atm. - 0.1 mbar) and four VSP 3000 (Atm. - 10-3 mbar) can be simultaneously connected
- brand new rugged VSP 3000 vacuum sensor made of plastics and ceramics with high chemical resistance
- rugged, splash-water proof VSP 3000 vacuum sensor, also for rough operating conditions
- VSP 3000 with wide measurement range from atmospheric pressure to fine vacuum
- for vacuum control from atmospheric pressure down to 10-3 mbar combine the CVC 3000 vacuum controller with gauge head VSP 3000 and vacuum solenoid valves of type VV-B. Suitable complete packages for fine vacuum control are available.
Technical data
- Vacuum sensor: VSP 3000
- Cable length of vacuum sensor: 2 m
- Upper measuring limit: 1 x 103 / 7.5 x 102 mbar/torr
- Lower measuring limit: 1 x 10-3 / 1 x 10-3 mbar/torr
- Measurement principle: Thermal conductivity (Pirani), chemically resistant plastics / ceramics
- Accuracy of measurement: +- 15% of indicated value in the range 0.01-10 mbar/hPa/torr
- Ambient temperature range (operation): 10 - 40 °C
- Ambient temperature range (storage): -10 - 60 °C
- Max. media temp. for continuous operation / short times: 40 / 80 °C
- Material of outer housing: Robust plastic housing with good chemical resistance
- Degree of protection: IP 20
- Degree of protection of front side (also built-in version): IP 42
- Max. power for VACUU·BUS® (24V DC): 4 A
- Cable length of external power supply: 2 m
- Interface: RS 232C
- Dimensions (L x W x H): 144 x 124 x 114 mm
- Weight: 0.44 kg
- Items supplied: Vacuum gauge with external vacuum sensor VSP 3000, ready for operation, with wall-plug power supply and manual.
17.6829.14 | Set DCP 3000 + VSP 3000 |